A smart relay with an adjustable on or off function. The delay can be adjusted from 0.1 second to 1 hour. The relay has one input and an output that is normally connected (NC) and another output that is normally open (NO).
The relay can only be set as either a delay on or delay off, but you can set two in series, so the first has a delay on and the last has a delay off.
The relay is max 10A and 250V for AC, 10A and 30V for DC.
Setup with jumpers
There is a lot of jumpers that can be adjusted for setting up the controllers.
If there is a jumper on S6, the controller will be delayed off. The controller will then always activate the relay when activated and after the set delay - deactivated.
If this jumper is placed on S7 instead, there is a delayed on. The relay will be off when the controller is powered and then it will be on after the delay is activated.
Setting up the delay
S1 = 0 and S2 = 1 and S4 = 0 |
0,13 to 1,3 seconds |
S1 = 0 and S2 = 1 and S4 = 1 |
1,5 to 14,5 seconds |
S1 = 1 and S2 = 0 and S4 = 0 |
0,5 to 5,25 seconds |
S1 = 1 and S2 = 0 and S4 = 1 |
6 to 58 seconds |
S1 = 0 and S2 = 0 and S4 = 0 |
4,4 to 42 seconds |
S1 = 0 and S2 = 0 and S4 = 1 |
48 to 463 seconds |
S1 = 1 and S2 = 1 and S4 = 0 |
38 to 340 seconds |
S1 = 1 and S2 = 1 and S4 = 1 |
389 to 3700 seconds |
Facts for Without enclosure
A smart relay with an adjustable on or off function. The delay can be adjusted from 0.1 second to 1 hour.
Vis fuld beskrivelse